Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod

Product Details
Customization: Available
Type: Alloy Steel Bar
Standard: AISI, ASTM, GB, JIS, DIN, BS
Manufacturer/Factory, Group Corporation
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
  • Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
  • Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
  • Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
  • Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
  • Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
Find Similar Products
  • Overview
  • Product Description
  • Surface Treatment
  • Process
  • Main Applications
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
303 Rod/Bar
Technique
Hot Rolled
Application
Structural Steel Bar, Tool Steel Bar, Die Steel Bar
Surface Treatment
Color Coated
Alloy
Non-alloy
Special Use
Mold Steel, Free Cutting Steel, Cold Heading Steel
Key Words
303 Bar/Rod
Thickness
2mm - 100mm
Outside Diameter
4.0 - 1219mm
Length
as Your Requirments
Diameter Tolerance
H9, H11, H13, K9, K11, K13 etc
Sample
Free-Sample
Surface
Lack, Peeled, Polishing, Bright, Sand Blast, Hl
MOQ
100kgs
Stock
in Stock
Transport Package
Wooden Package
Specification
303
Trademark
LORK
Origin
China
HS Code
7219350000
Production Capacity
50000kg/Month

Product Description

Product Description

Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel RodSpot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod

Introduction

The machineable nature of Grade 303 stainless steel is due to the presence of Sulphur in the steels composition. Whilst the Sulphur improves machining, it also causes a decrease in the corrosion resistance and a slight lowering of the toughness. The corrosion resistance of grade 303 stainless steel is lower than that for 304. The toughness is still excellent as with other austenitic grades.


Composition

 Chemical composition for stainless steels alloy 303

%

303

C

0-0.10

Mn

0-2.0

Si

0-1.0

P

0-0.4

S

0-0.15

Cr

17-19

Ni

8-10

Fe

balance

 


Grade Specification

Grade UNS DIN EN AMS ASTM BS
303

S30300

- 1.4305     303S31

 

Mechanical Properties

Mechanical properties for stainless steel alloy 303 bar

Grade

303

Tensile Strength (MPa)

500-750 MPa

Proof Stress (MPa)

190 Min MPa

Elongation A5 mm

35 Min %

Hardness Brinell

230 Max HB

 

Physical Properties

Physical properties for stainless steel alloy 303

Property

Value

Density

8.03 kg/m3

Melting Point

1455°C

Modulus of Elasticity

193 GPa

Electrical Resistivity

0.72 x 10-6 Ω.m

Thermal Conductivity

16.3 W/m.K

Thermal Expansion

17.3 x 10-6/K


Characteristic

Corrosion Resistance

Sulphur additions to the composition act as initiation sites for pitting corrosion. This decreases the corrosion resistance of grade 303 stainless steel to less than that for 304. However corrosion resistance remains good in mild environments.

In chloride containing environments over 60°C, grade 303 stainless steel is subject to pitting and crevice corrosion. Grade 303 stainless is not suitable for use in marine environments.

Heat Resistance

Grade 303 stainless steel has good resistance to oxidation when intermittently exposed to temperature up to 760°C temperatures. It also has good oxidation resistance in continuous service to 870°C. This, however, is not recommended as 303 is sensitive to carbide precipitation with continuous use at 425-860°C.

Cold Working

Type 303 is not readily cold workable. Some cold working is possible but sharp bending should not be attempted.

Hot Working

Fabrication methods, like forging, that involve hot working like should occur after uniform heating to 1149-1260°C. The fabricated components should then be rapidly cooled to ensure maximum corrosion resistance.

Heat Treatment

Grade 303 stainless steel cannot be hardened by heat treatment.

Solution treatment or annealing can be done by rapid cooling after heating to 1010-1120°C.

Machinability

Grade 303 stainless steel has excellent machinability. Machining can be enhanced by adhering to the following rules:

  • Cutting edges must be kept sharp. Dull edges cause excess work hardening.
  • Cuts should be light but deep enough to prevent work hardening by riding on the surface of the material.
  • Chip breakers should be employed to assist in ensuring swarf remains clear of the work
  • Low thermal conductivity of austenitic alloys results in heat concentrating at the cutting edges. This means coolants and lubricants are necessary and must be used in large quantities.

Welding

The sulphur addition present in Grade 303 stainless steel results in poor weldability. If Grade 303 stainless steel must be welded the recommended filler rods or electrodes are grades 308L and 309 stainless steels. For maximum corrosion resistance, the welds must be annealed.


Applications

The application of 303 stainless steel in the medical field mainly includes the manufacture of surgical instruments, medical equipment and implants. 303 stainless steel has good biocompatibility and corrosion resistance, which can ensure good compatibility with the biological environment, so it is widely used in the medical field. Specific applications include:

Surgical instruments: 303 stainless steel is used to manufacture surgical instruments such as blades, scissors, pliers, etc., which can work stably during surgery due to its corrosion resistance and good mechanical properties.

Medical equipment: In the manufacture of medical equipment, 303 stainless steel is used to manufacture the outer shell and internal structure of various medical devices to ensure the corrosion resistance and long-term stability of the equipment.

Implants: Due to its biocompatibility, 303 stainless steel is also used to manufacture orthopedic implants, heart valves, etc., to help patients recover after surgery.

These applications not only demonstrate the diversity and importance of 303 stainless steel in the medical field, but also reflect its superiority in corrosion resistance, biocompatibility and mechanical properties.


 

Surface Treatment

 
Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
 
 

Process

Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod

 

 

Main Applications

Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod

 

 

 
 

Company Profile

 
Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
 
 
 

Packaging & Shipping

 
Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
 
 
 
Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod
 
 
 

FAQ

Spot Product S30300/1.4305 Alloy Stainless Steel Bar for Orthopedic Implants Medical Materials 303 Steel Rod

 

 

 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed